FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package nictiz.fhir.nl.r4.cio#1.0.0-beta.5 (78 ms)

Package nictiz.fhir.nl.r4.cio
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=nictiz.fhir.nl.r4.cio@1.0.0-beta.5&canonical=http://nictiz.nl/fhir/StructureDefinition/cio-ReplyProposalContraIndication
Url http://nictiz.nl/fhir/StructureDefinition/cio-ReplyProposalContraIndication
Version 1.0.0-beta.5
Status draft
Name CioReplyProposalContraIndication
Title cio ReplyProposalContraIndication
Experimental False
Realm nl
Description Profile on the Communication resource which represents the reply proposal contraindication conform information standard [CiO](https://informatiestandaarden.nictiz.nl/wiki/Landingspagina_Contra-indicaties_en_Overgevoeligheden).
Purpose To define the reply proposal contraindication as stated in the information standard CiO.
Copyright Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.
Type Communication
Kind resource

Resources that use this resource

CapabilityStatement
http://nictiz.nl/fhir/CapabilityStatement/cio-ReplyProposalContraIndication cio ReplyProposalContraIndication
http://nictiz.nl/fhir/StructureDefinition/cio-ReplyProposalContraIndication-Bundle cio ReplyProposalContraIndication Bundle

Resources that this resource uses

StructureDefinition
http://nictiz.nl/fhir/StructureDefinition/nl-core-HealthProfessional-PractitionerRole nl core HealthProfessional PractitionerRole
http://nictiz.nl/fhir/StructureDefinition/nl-core-Patient nl core Patient
http://nictiz.nl/fhir/StructureDefinition/pattern-NlCoreHealthProfessionalReference Reference
http://nictiz.nl/fhir/StructureDefinition/cio-MedicationContraIndication cio MedicationContraIndication
http://nictiz.nl/fhir/5.0/StructureDefinition/extension-Communication.payload.content%5Bx%5D:contentCodeableConcept extension Communication.payload.contentCodeableConcept
http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.26.11.38--20240709000000 BeantwoordingVoorstelContraIndicatie


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "cio-ReplyProposalContraIndication",
  "url" : "http://nictiz.nl/fhir/StructureDefinition/cio-ReplyProposalContraIndication",
  "version" : "1.0.0-beta.5",
  "name" : "CioReplyProposalContraIndication",
  "title" : "cio ReplyProposalContraIndication",
  "status" : "draft",
  "publisher" : "Nictiz",
  "contact" : [
    {
      "name" : "Nictiz",
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.nictiz.nl",
          "use" : "work"
        }
      ]
    }
  ],
  "description" : "Profile on the Communication resource which represents the reply proposal contraindication conform information standard [CiO](https://informatiestandaarden.nictiz.nl/wiki/Landingspagina_Contra-indicaties_en_Overgevoeligheden).",
  "purpose" : "To define the reply proposal contraindication as stated in the information standard CiO.",
  "copyright" : "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "fhirVersion" : "4.0.1",
  "mapping" : [
    {
      "identity" : "cio-dataset-200-beta3-20241023",
      "uri" : "https://decor.nictiz.nl/pub/cio/cio-html-20241023T071643/ds-2.16.840.1.113883.2.4.3.11.60.26.1.2-2020-04-02T000000.html",
      "name" : "ART-DECOR Dataset Contraindications and hypersensitivities 2.0.0-beta.3 20241023"
    }
  ],
  "kind" : "resource",
  "abstract" : false,
  "type" : "Communication",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Communication",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Communication",
        "path" : "Communication",
        "short" : "ReplyProposalContraIndication",
        "definition" : "The response to the proposal for registering, retracting, or modifying a medication contraindication.",
        "comment" : "Since all concepts within the ReplyProposalContraIndication building block are mapped to elements within this profile, it is not necessary to use the [cio-RegistrationInformation](http://nictiz.nl/fhir/StructureDefinition/cio-RegistrationInformation) profile to convey the RegistrationInformation concepts.",
        "alias" : [
          "AntwoordVoorstelContraIndicatie"
        ],
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-937",
            "comment" : "ReplyProposalContraIndication"
          },
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-943",
            "comment" : "RegistrationInformation"
          }
        ]
      },
      {
        "id" : "Communication.meta",
        "path" : "Communication.meta"
      },
      {
        "id" : "Communication.meta.tag",
        "path" : "Communication.meta.tag",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 1
      },
      {
        "id" : "Communication.meta.tag:actionable",
        "path" : "Communication.meta.tag",
        "sliceName" : "actionable",
        "min" : 1,
        "max" : "1",
        "patternCoding" : {
          "system" : "http://terminology.hl7.org/CodeSystem/common-tags",
          "code" : "actionable"
        }
      },
      {
        "id" : "Communication.identifier",
        "path" : "Communication.identifier",
        "short" : "IdentificationNumber",
        "definition" : "Globally unique number that identifies the instantiation of the information model. The number is composed of an identification of the issuer organization and a unique number assigned by this organization.",
        "alias" : [
          "Identificatienummer"
        ],
        "min" : 1,
        "max" : "1",
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-780",
            "comment" : "IdentificationNumber"
          }
        ]
      },
      {
        "id" : "Communication.basedOn",
        "path" : "Communication.basedOn",
        "short" : "RelationProposalContraIndication",
        "definition" : "Relation to the proposal contraindication to which the reply is made.",
        "alias" : [
          "RelatieVoorstelContraIndicatie"
        ],
        "min" : 1,
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Resource",
              "http://nictiz.nl/fhir/StructureDefinition/cio-MedicationContraIndication"
            ]
          }
        ],
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-945",
            "comment" : "RelationProposalContraIndication"
          }
        ]
      },
      {
        "id" : "Communication.subject",
        "path" : "Communication.subject",
        "short" : "Patient",
        "definition" : "The patient that was the focus of this communication.",
        "alias" : [
          "Patient"
        ],
        "min" : 1,
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Patient",
              "http://nictiz.nl/fhir/StructureDefinition/nl-core-Patient"
            ]
          }
        ],
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-302",
            "comment" : "Patient"
          }
        ]
      },
      {
        "id" : "Communication.sent",
        "path" : "Communication.sent",
        "short" : "CreationDateTime",
        "definition" : "Date and of the response to the proposal.",
        "alias" : [
          "OntstaansDatumTijd"
        ],
        "min" : 1,
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-783",
            "comment" : "CreationDateTime"
          }
        ]
      },
      {
        "id" : "Communication.sender",
        "path" : "Communication.sender",
        "short" : "Author",
        "definition" : "Author of the response to the proposal.",
        "alias" : [
          "Auteur"
        ],
        "min" : 1,
        "type" : [
          {
            "code" : "Reference",
            "profile" : [
              "http://nictiz.nl/fhir/StructureDefinition/pattern-NlCoreHealthProfessionalReference"
            ],
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Practitioner",
              "http://hl7.org/fhir/StructureDefinition/PractitionerRole",
              "http://nictiz.nl/fhir/StructureDefinition/nl-core-HealthProfessional-PractitionerRole"
            ]
          }
        ],
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-781",
            "comment" : "Author"
          }
        ]
      },
      {
        "id" : "Communication.payload",
        "path" : "Communication.payload",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "exists",
              "path" : "content.extension(url='http://nictiz.nl/fhir/5.0/StructureDefinition/extension-Communication.payload.content%5Bx%5D:contentCodeableConcept')"
            }
          ],
          "rules" : "open"
        },
        "min" : 1,
        "max" : "2"
      },
      {
        "id" : "Communication.payload:responseProposalContraIndication",
        "path" : "Communication.payload",
        "sliceName" : "responseProposalContraIndication",
        "min" : 1,
        "max" : "1"
      },
      {
        "id" : "Communication.payload:responseProposalContraIndication.content[x]",
        "path" : "Communication.payload.content[x]",
        "type" : [
          {
            "code" : "string"
          }
        ]
      },
      {
        "id" : "Communication.payload:responseProposalContraIndication.content[x].extension",
        "path" : "Communication.payload.content[x].extension",
        "min" : 1
      },
      {
        "id" : "Communication.payload:responseProposalContraIndication.content[x].extension:contentCodeableConcept",
        "path" : "Communication.payload.content[x].extension",
        "sliceName" : "contentCodeableConcept",
        "comment" : "This is a pre-adopt of R5 in which the string data type of `.payload.content` is changed to a CodeableConcept.",
        "min" : 1,
        "type" : [
          {
            "code" : "Extension",
            "profile" : [
              "http://nictiz.nl/fhir/5.0/StructureDefinition/extension-Communication.payload.content%5Bx%5D:contentCodeableConcept"
            ]
          }
        ]
      },
      {
        "id" : "Communication.payload:responseProposalContraIndication.content[x].extension:contentCodeableConcept.value[x]",
        "path" : "Communication.payload.content[x].extension.value[x]",
        "short" : "ResponseProposalContraIndication",
        "definition" : "The response to the proposal for registering, retracting, or modifying a medication contraindication. The proposed medication contraindication is either accepted or rejected.",
        "alias" : [
          "BeantwoordingVoorstelContraIndicatie"
        ],
        "min" : 1,
        "binding" : {
          "strength" : "required",
          "valueSet" : "http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.26.11.38--20240709000000"
        },
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-944",
            "comment" : "ResponseProposalContraIndication"
          }
        ]
      },
      {
        "id" : "Communication.payload:comment",
        "path" : "Communication.payload",
        "sliceName" : "comment",
        "max" : "1"
      },
      {
        "id" : "Communication.payload:comment.content[x]",
        "path" : "Communication.payload.content[x]",
        "short" : "Comment",
        "definition" : "Textual explanation of the response to the proposal contraindication. This free text field can be used to provide the reason for rejecting the proposed medication contraindication.",
        "alias" : [
          "Toelichting"
        ],
        "type" : [
          {
            "code" : "string"
          }
        ],
        "mapping" : [
          {
            "identity" : "cio-dataset-200-beta3-20241023",
            "map" : "cio-dataelement-20-942",
            "comment" : "Comment"
          }
        ]
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.